| Standard Particulars |
| Send Inquiry |
 |
| Drawing No. |
|
HC- PN 1101 |
HC- PN 1102 |
HC- PN 1103 |
PC-PN 1104 |
| Highest System Voltage |
KV |
12 |
12 |
12 |
12 |
| Working Voltage |
KV |
11 |
11 |
11 |
11 |
| Creepage Distance Minimum |
MM |
230 |
230 |
280 |
320 |
| Visible Discharge Voltage |
KV |
9 |
9 |
9 |
9 |
| Mechanical failing Load |
KN |
5 |
5 |
10 |
10 |
Power Frequency withstand
voltage |
Wet |
KV |
525 |
35 |
45 |
45 |
| Dry |
KV |
45 |
45 |
55 |
65 |
Power Frequency Flashover
Voltage |
Wet |
KV |
45 |
45 |
55 |
55 |
| Dry |
KV |
55 |
55 |
65 |
75 |
| Impulse Withstand Voltage |
KVp |
75 |
75 |
75 |
75 |
| Puncture Voltage |
KV |
105 |
105 |
105 |
110 |
| thimble-IS : 2486 ( Part II ) / BS : 3288 ( Part II ) |
Small |
Small |
Small/Large |
Small/Large |
| Net Weight (aaprox) |
Kg. |
1.0 |
1.2 |
1.5 |
2.2 |
| Specification as per IS : 731, BS : EN 60383, IEC : 383 |
| Insulator can be supplied with or without radio-Free Glaze |
| Send Inquiry |
Pin Insulator 22 Kv

Pin Insulators of one piece or multi piece constructions are widely used in low cost distribution lines. Multi-piece construction makes these Insulators less vulnerable to damage as with one shell broken a multi-piece insulator can normally withstand the line voltage for a considerable time without difficulty.
| Standard Particulars |
| Send Inquiry |
 |
| Drawing No. |
|
HC- PN 1101 |
HC- PN 1102 |
HC- PN 1103 |
PC-PN 1104 |
| Highest System Voltage |
KV |
24 |
24 |
24 |
24 |
| Working Voltage |
KV |
22 |
22 |
22 |
22 |
| Total Creepage Distance (Normal) |
MM |
432 |
560 |
600 |
620 |
| Protected Creepage Distance (Normal) |
MM |
210 |
290 |
320 |
330 |
| Visible Discharge voltage |
KV |
18 |
18 |
18 |
18 |
| Mechanical Failing Load |
KN |
10 |
10 |
10 |
10 |
Power Frequency withstand
voltage |
Wet |
KV |
55 |
75 |
60 |
60 |
| Dry |
KV |
65 |
85 |
70 |
75 |
Power Frequency Flashover
Voltage |
Wet |
KV |
65 |
85 |
70 |
70 |
| Dry |
KV |
75 |
95 |
80 |
85 |
| Impulse Withstand Voltage |
Positive |
KVp |
140 |
150 |
140 |
140 |
| Negative |
KVp |
150 |
160 |
150 |
150 |
| Puncture Voltage |
KV |
140 |
150 |
150 |
150 |
| Thimble-IS : 2486 ( Part II ) / BS : 3288 ( Part II ) |
Large |
Large |
Large |
Large |
| Net Weight (aaprox) |
Kg. |
4.5 |
7.0 |
4.5 |
4.5 |
| Specification as per IS : 731, BS : EN 60383, IEC : 383 |
| Insulator can be supplied with or without radio-Free Glaze |
| Send Inquiry |
Pin Insulator 33 Kv

Pin Insulators of one piece or multi piece constructions are widely used in low cost distribution lines. Multi-piece construction makes these Insulators less vulnerable to damage as with one shell broken a multi-piece insulator can normally withstand the line voltage for a considerable time without difficulty.
| Standard Particulars |
| Send Inquiry |
 |
| Drawing No. |
|
HC- PN 1101 |
HC- PN 1102 |
HC- PN 1103 |
PC-PN 1104 |
| Highest System Voltage |
KV |
36 |
36 |
36 |
36 |
| Working Voltage |
KV |
33 |
33 |
33 |
33 |
| Total Creepage Distance (Normal) |
MM |
580 |
670 |
700 |
740 |
| Protected Creepage Distance (Normal) |
MM |
300 |
325 |
335 |
355 |
| Visible Discharge voltage |
KV |
27 |
27 |
27 |
27 |
| Mechanical Failing Load |
KN |
10 |
10 |
10 |
10 |
Power Frequency withstand
voltage |
Wet |
KV |
75 |
80 |
85 |
90 |
| Dry |
KV |
85 |
95 |
100 |
105 |
Power Frequency Flashover
Voltage |
Wet |
KV |
85 |
90 |
95 |
100 |
| Dry |
KV |
95 |
105 |
110 |
115 |
| Impulse Withstand Voltage |
Positive |
KVp |
170 |
190 |
200 |
200 |
| Negative |
KVp |
180 |
200 |
210 |
210 |
| Puncture Voltage |
KV |
180 |
200 |
200 |
210 |
| Thimble-IS : 2486 ( Part II ) / BS : 3288 ( Part II ) |
Large |
Large |
Large |
Large |
| Net Weight (aaprox) |
Kg. |
7.0 |
10.0 |
9.5 |
12.0 |
| Specification as per IS : 731, BS : EN 60383, IEC : 383 |
| Insulator can be supplied with or without radio-Free Glaze |
| Send Inquiry |